IPC Systems Ltd. - PRODUCT NEWS

 


600 Series Dynamic Signal Analyser.

Features
* Analysis rates are software programmable from 20 Hz to 40 kHz
* 24-bit Sigma Delta ADC per analogue input
* Spurious-free dynamic range of 108dB (typical)
* AC/DC coupling, software selectable per channel
* TEDS support
* Pseudo-differential input
* Total harmonic distortion of -100 dB (typical)
* Channel-to-channel phase matching of <0.12 degrees at 1 kHz
* 8-bit digital IO port
* Power input of 6 to 16 VDC
* USB2 and 10/100BaseT Ethernet versions (Ethernet Versions available May 2007)

640 Model
* 4 analogue inputs, ±10V input range (±60V max without damage)
* 2.1 mA IEPE current source per channel (20V compliance)
* 1.0 Hz AC Coupling HPF
* 24-bit Sigma Delta DAC analogue output
* Analogue outputs: sine, swept sine, random, burst and arbitrary
* Analogue output signal-to-noise ratio:100 dB (typical)

650 Model
* 5 analogue inputs, ±40V input range (±60V max without damage)
* 2.1 mA IEPE current source per channels 1-4 (20V compliance)
* 0.1 Hz AC coupling HPF

Vibration data acquisition, analysis, and monitoring has never been easier than with the new IOtech 600 Series of dynamic signal analysers and eZ-Series software. More than 30 years of engineering experience in vibration measurements have gone into the design of the 600 Series of DSAs. They come in either USB or Ethernet versions for maximum flexibility. The DSA hardware provides signal conditioning and data acquisition, while the eZ-Series PC-based software provides monitoring and analysis functions.

Noise, Vibration, & Harshness Testing Applications
If output source excitation is not required, the 650 Model provides 5 input channels. The extra input channel can be useful for in-vehicle NVH applications that require data correlation to Tachometer inputs. The eZ-Series software packages are the software of choice for these applications. Data recording, resonance testing, balancing and production quality testing functions are supported in the eZ-Series software. The Windows®-style graphical user interface allows operators to easily select hardware parameters and access widely used analysis modules. The system supports resolution from 64 to 25,600 spectral lines, and frequency ranges from DC to 40 kHz. The 600 Series DSA was designed specifically for Noise, Vibration and Harshness (NVH) testing applications. Either the 640 or 650 Model can be used for this application. The 640 Model provides 4 input channels, each with an input range of ±10V. Additionally, the 640 Model is a valued portable vibration test equipment by virtue of its programmable analogue output channel that generates continuous or swept sine-wave signals, as well as sine, random, burst and arbitrary signals. In addition, it can output these signals while receiving analogue input data. The software synchronizes the signals between the ADC and the DAC within the unit.

Rotating Machinery, and Predictive Maintenance Applications
The 600 Series DSA was designed specifically for rotating machinery monitoring and predictive maintenance applications. Again, either the 640 or 650 Model can be used for this application. The 650 Model provides 5 input channels each with an input range of ±40V. The higher voltage range can be especially convenient for connection to proximity sensors (Eddy Current Probes) that operate from a -24 VDC supply. In addition, it accommodates both IEPE and voltage-type sensors providing greater flexibility than other instruments that only support IEPE-type sensors. Tachometer signals can be connected to any input channel. If output source excitation is required or a lower input voltage range is desired, the 640 Model can be selected. The output source is useful for structure excitation with shakers. The eZ-Series software packages are the software of choice for these applications. Transient and steady state data recording, limit checking, resonance testing, multi-plane balancing and rotating machinery analysis functions are supported in the eZ-Series software. The Windows®-style graphical user interface allows operators to easily select hardware parameters and access widely used analysis modules. The system supports resolution from 64 to 25,600 spectral lines, and frequency ranges from DC to 40 kHz.

Input Impedance 640e/640u 650e/650u
High to ground 200k Ohm || 130p 800k Ohm || 120p
Low to ground 1k Ohm 1k Ohm
High to low 201k Ohm 801k Ohm
Specifications
General Specifications Environment
Operating Temperature
640u and 650u: -30°C to 70°C
640e and 650e: 0°C to 50°C
Humidity: 0° to 95% RH, non-condensing
Vibration: IEC 600068-2-64
Shock: IEC 600068-2-27
Emissions: EN61326, 89/366EEC
Safety: EN61010
Ingress: IP 40
Power Consumption
640e, 650e: 5.0W max
640u, 650u: 2.5W max
Input Power Range: 6 to 16 VDC
PC Communication
640e, 650e: 10/100BaseT Ethernet
640u, 650u: USB 2.0
Dimensions: 142.24 mm W x 180.34 mm D x 38.1 mm H
(5.6" x 7.1" x 1.5")
Weight: 675 g (1.5 lbs)
Warm-Up: 30 minutes to rated specifications
Analogue Specifications
Analogue Measurements
ADC Converter Resolution: 24 bits
ADC Converter Type: Delta-sigma
Sample Rates: Up to 105,468 samples per second (software dependent)
Sample Rate Accuracy: ±50 ppm
Channels
640e, 640u: 4 input channels
650e, 650u: 5 input channels
Input Connector: 1 BNC per channel
Input Coupling: DC, AC, or AC + IEPE; software programmable per channel basis
High-Pass Filter (AC Coupling Cutoff)
640e, 640u: 1.0 Hz
650e, 650u: 0.1 Hz
Input Ranges
640e, 640u: ±10V peak
650e, 650u: ±40V peak
Input Protection: ±60V max without damage
Over-Range Indication: Software
Low-Pass Filter: Software programmable per channel
Type: Anti-aliasing hardware 3-pole 360 kHz, software selectable FIR filter. Any aliasing above 27 MHz is lost in the noise floor of 64k FFT.

Amplitude Accuracy
Amplitude -3 dB: 0.49 x sample rate
Amplitude Flatness: ±0.05 dB typ ±0.10 dB max DC to 20 kHz
Total Harmonic Distortion: -100 dB typical 1 kHz -97 dB typical 10 kHz
SFDR Including Harmonics: 108 dB typical DC to 50 kHz
SFDR -60dB: 128 dB typical DC to 50 kHz
Channel-to-Channel Crosstalk: <-100 dB at 1 kHz
Channel-to-Channel Phase Matching
640e, 640u: <0.04¢ª/kHz + 0.08¢ª
650e, 650u: <0.06¢ª/kHz + 0.1¢ª
Common Mode Rejection Ratio: -70 dB typ -55 dB max at 1 kHz
Wideband Noise:
640e, 640u: <46 µV RMS typ 76 µV RMS max
650e, 650u: <184 µV RMS typ 304 µV RMS max
IEPE Bias Source (640, 640u, 650, 650u channels 1 to 4)
Current: 2.1 mA, 21V compliance (on/off software programmable per channel)
Impedance: >255k Ohm
IEPE Fault Detection Thresholds: <1V (short), >20V (open)
IEPE Fault Indication: Software indicator, per channel

Analogue Output (640e, 640u only)
Channels: 1
Signal Connection: BNC
Frequency Range: DC to 45 kHz (-0.25 dB)
Frequency Accuracy: ±50 ppm
DAC Resolution: 24 bit
DAC Update Rate: 93.75 KSps
DAC Type: Delta-sigma; initial value 0.0V for 640e and 650e; not guaranteed
for 640u and 650u
Amplitude Settings: 0 to 7V p-p or 0 to 3.5V peak
Amplitude Accuracy at 1 kHz: ±0.05 dB typ ±0.12 dB max
Amplitude Flatness (DC to 20kHz): ±0.02 dB typ ±0.1 dB max
SNR (DC to 20 kHz): 100 dB typ 90 dB max
Maximum Load: 1k Ohm (50 Ohm with external power)
Waveform Modes: Sine, swept sine, random, burst, arbitrary
Output Impedance: 50 Ohm

Tachometer Inputs
Any analogue input channel may be used as a tachometer input

Digital I/O Lines
Note: To make use of Digital I/O, eZ-TOMAS or eZ-NDT software must be running in the host PC.
Channels: 8 Digital I/O, programmable as inputs or outputs on a line by line basis
Ports: 1 x 8-bit; each bit is programmable as input or output
Power-Up Mode: Inputs pulled low
Connector: DB9 female
Input Scanning Modes: 2 programmable scanning modes
Asynchronous, under program control at any time relative to Analogue scanning;
Synchronous with Analogue scanning
Input Protection: ±5.6V
Input: Levels:
Low: 0 to +0.8V
High: +2.0V to +5.0V
Output Pull-Down Resistor: 10k Ohm
Output Voltage Range: 0 to +3.3V, may be pulled up to +5V
Output Resistance: 100 Ohm
Output Levels:
Low: <0.8V
High: >3.0V with no load
Sampling: 105,468 Hz, maximum
Output Timing: Outputs are always written asynchronously



640u USB Dynamic Signal Analyser with 1 eZ-Series Software Package (eZ-Analyst, eZ-TOMAS or eZ-Balance) £7995
640u USB Dynamic Signal Analyser with eZ-NDT £8495
650u USB Dynamic Signal Analyser with 1 eZ-Series Software Package (eZ-Analyst, eZ-TOMAS or eZ-Balance) £7995
650u USB Dynamic Signal Analyser with eZ-NDT £8495
640e Ethernet Dynamic Signal Analyser with 1 eZ-Series Software Package (eZ-Analyst, eZ-TOMAS or eZ-Balance) (Available May 2007) £8495
640e Ethernet Dynamic Signal Analyser with eZ-NDT (Available May 2007) £8995
650e Ethernet Dynamic Signal Analyser with 1 eZ-Series Software Package (eZ-Analyst, eZ-TOMAS or eZ-Balance) (Available May 2007) £8495
650e Ethernet Dynamic Signal Analyser with eZ-NDT (Available May 2007) £8995
Software Overview

Four end user software packages are available for the 600 Series, each tailored to a particular type of vibration measurement and analysis application. Select the package that best suits your application now, and upgrade to additional packages as your requirements evolve.


For more information, click here...

March 2007

Home - Website - Search - Suppliers - Links - New Products - Catalogues - Magazines