IPC Systems Ltd. - PRODUCT NEWS
MSR12, Modular Signal Recorder
The MSR 12 is a practical, portable signal acquisition instrument for measuring, displaying and recording a range of physical parameters. Its unique modular design means that users can customise the unit according to their specific requirements.
Due to its modular design the MSR 12 can easily be customised by adding or replacing modules to provide the required functionality.Each module has a range of sensors mostly of a similar type. For test purposes the gradient curve and the actual measurement parameters for the selected sensor may be shown on the unit's display. The readings are processed by the module's own processor and saved in the modules memory.
The base module of the MSR 12 includes a temperature sensor, a pressure sensor and three accelerometers (X, Y and Z-axes). A list of additional modules and sensors may be found at the bottom of this page:
Features:
* Large Multi-Function Display with Automatic Backlight
* Hand-held unit
* Standard modules include 3-axis accelerometer, air pressure, ambient air temperature
* Two expansion slots available for at least two further internal modules
* Memory capacity of over 1,000,000 measurements per module
* Sampling rate of up to 10 000 measurements per second
* Storage rates of up to 1000 measurements per second
* Analogue and Digital input options
* Built in real-time clock
* PC software included as standard
* Compact & Lightweight weighing only 180g, measures 137x74x27mmAvailable Modules:-
The 3ACCF Accelerometer Module
The 3ACCF accelerometer module processes and logs measurements from an external acceleration sensor.
* Display/Measurement range: ± 10 G
* Display resolution: 0.001 G
* Measurement rate: 1000 /s to 1 every 30Sec
* Storage Capacity of 4,000,000 measurements per axis
* Storage rates every nth measurement value is stored (n = 1-256)
A2D5HUM1 Analogue, Digital, Temperature & Humidity ModuleThe A2D5HUM1 plug-in module records two input voltages, the level of five digital inputs, the signal from one humidity sensor and the temperature of the humidity sensor.
Either the instantaneous value or the average, minimum and maximum values can be logged. In addition, a threshold value can be set and an event triggered should this threshold be exceeded.
Module A2D5:
* Display/Measurement range: Voltage: 0-3 V Digital level: 0-3 V
* Display resolution: Voltage: 10 Bit Digital level: 1 Bit
* Measurement Rate: 100 /s, 10 /s, 1 /s, every 10 s, every 30 s, every 60 s
* Input: 2 x voltage, 5 x digital level
* Storage Capacity of 1 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)
Module HUM1:
* Display/Measurement range: 0-100 % relative humidity -20 °C to 60 °C
* Display resolution: 0.01 % 0.01 °C
* Measurement Rate:1/s, every 10s, every 30s, every 60s
* Input: 1 x humidity and temperature
* Storage Capacity of 1 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)AIN4-10 Analogue Input Module:
The universal module AIN4-10 records and logs four input voltages
Features:
* Display/Measurement range: Voltage: 0-3.0 V Input voltage divider, optional (max. 48 V)
* Display resolution: Voltage: 10 bit
* Measurement Rate: 100 /s, 50 /s, 20 /s, 10 /s, 5 /s, 2 /s, 1 /s
* Input: 4 Analogue Inputs
* Storage Capacity of 1 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)AIN4-12 Analogue Input Module
The universal module AIN4-12 records and logs four input voltages
Features:
* Display/Measurement range: Voltage: 0-2.4 V Input voltage divider, optional (max. 48 V)
* Display resolution: Voltage: 12 bit
* Measurement Rate: 1000/s, 200/s, 500/s, 100 /s, 50 /s, 20 /s, 10 /s, 5 /s, 2 /s, 1 /s
* Input: 4 Analogue Inputs
* Storage Capacity of 4 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)ECG - Electrocardiogram Module
This plug-in module serves to record an ECG signal. The unit can also compute the pulse (heart rate).
Features:
* Display/Measurement range: ECG / Pulse
* Display resolution: ECG: 1 value Pulse: 1 bpm
* Measurement Rate: 200 Hz
* Storage Rate: ECG: 200 /s, 100 /s, 50 /s Pulse: 1 /s, 1/ 10 s, 1/ 30 s, 1/ 60 s
* Input: ECG signal with 3 electrodes (optional 2 ECG)
* Memory Capacity: 4 000 000 measurementsHR - Heart Rate Module
The HR plug-in module processes and logs the heart rate (pulse) measured by the POLAR transmitter chest strap.
Features:
* Display/Measurement range: Pulse (heart beats per minute)
* Display resolution: 1bpm (beat per minute)
* Input: Radio signal from the POLAR transmitter chest strap
* Mode of Operation: Following each heart beat the heart rate (heart beats per minute) is recalculated. The measurement rate determines how often the MSR 12 logs the last calculated heart rate. The storage rate determines how often the heart rate is stored.
* Storage Capacity of 1 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)PR8 - Pressure Module
The PR8 pressure module processes and logs pressure and temperature values from external pressure sensors.
* Display/Measurement range: 0-15 000 mbar, -10 °C to +60 °C
* Display resolution: 1 mbar/1 °C
* Input: Max 8 Pressure Sensors
* Measurement rate: 20 /s to 1 every 60 Sec
* Storage Capacity of 1 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)T24HUM8 - Humidity & Temperature Module
The T24HUM8 additional module for the MSR 12 processes and logs the values measured by external temperature or humidity sensors.
* Display/Measurement range: ±150°C, 0-100% relative humidity.
* Display resolution: 0.01%, 0.01°C
* Input: Max 24 Temperature & 8 Humidity Sensors
* Measurement rate: 1 sec intervals to 1 every 60 Sec
* Storage Capacity of 2 000 000 measurements
* Storage rates every nth measurement value is stored (n = 1-256)Valve-Tester Module
The valve tester measures the delay time between the control pulse and the output signal. It logs this time together with the value of the output signal and a time stamp. In addition, the delay time is analysed.
Features:
* Measurement range: Voltage: 0-2.7 V Delay time: 0-30 000 ms Counter: 23 Bit
* Display resolution: Voltage: 12 bit Delay time: 1 ms Counter: 1bit
Input: 4 analogue inputs for optional use as
Voltage input
Analogue pressure input
Digital input 0-10 V
Digital optoelectronic coupler input
Digital input with photo diodeEach input can be defined as a control pulse of an output signal
* Measurement rate: Selectable up to 10 kHz
* Storage Capacity of 1 000 000 measurements
* Storage rate: All measured delay times