RDP Electronics Ltd. - PRODUCT NEWS








LVDT and digital indicator combination provide cost effective means of measuring roller gap separation

The measurement of the position of the roll bearing on the inside rollers is an essential requirement in a number of precision manufacturing processes. It is a measurement task that can be achieved simply and cost-effectively using an RDP E725 digital indicator in combination with an LVDT.

RDP Electronics Ltd’s E725 amplifier indicator can be set to display the average gap and run out across the width of the roller. A special feature of the E725 allows the transducers to be re-zeroed without actually drawing the rollers together. Typically this is achieved by using a 1mm spacer and programming the E725 when pressing the zero button to read 1mm rather than zero.

Further guidance and advice about the E725 and LVDT combination can be obtained from the RDP engineering support team on 01902 457512 and specification information viewed online at www.rdpe.com/uk/e725.htm and www.rdpe.com/uk/men-disp.htm .

__________________________________________________

For more information, please contact :-

RDP Electronics Ltd
Grove Street, Heath Town, Wolverhampton WV10 0PY. UK
Tel: +44(0)1902 457512
Email:
sales@rdpe.com
Website: www.rdpe.com

July 2012